Röhrendaten/ Tube Data:
Röhrendaten/ Tube Data | |
Brand: | Rodan |
Manufacturer: | Okaya Electric Industries Company, Limited |
Made in: | Tokyo, Japan |
Tube Type: | CD47/GR-411 similar to CD47/GR-414 |
Overall Height: | 220mm (8 ¼ = 8.66") including pins and center post |
Diameter Base: | 72mm (2.83") |
Digit Height: | 135mm (5 1/8 = 5.31") tall numerals 0-9 |
Base: | B12A (Duodecal Base) |
Displayed Symbols: | 0-9 |
Min. Supply: | 250V |
Min. Ionization: | 250V |
Typical maint. Volt. | 160V |
Min. Cathode Curr. | 17.5mA |
Typ. Cathode Curr. | 25mA |
Max. Cathode Curr. | 32,5mA |
Nuber of Pins: | 12 |
Pin Diameter | 2.36mm (= 0.093") |
Pin Circle: | 27mm (= 1.063") |
Pin Spacing: | 30° |
Pin Length: | 11.1 mm |
Spigot: | 15.5mm (0.610") dia. Splined Center Spigot |
Aligment Method: | Spline in Front |
Minimum Supply Voltage: | 250VDC |
Recommended Plate Resistor for 250VDC: | 5.1kOhms / 1Watt |
Recommended Plate Resistor for 300VDC: | 6.8kOhms / 2Watt |
Plate Voltage: | 200VDC |
Min Cathode Current | 17.5mA |
Average Cathode Current | 25mA |
Max Cathode Current | 32.5mA |
Abs.max Kathode Current | 35mA |
Storage Temperature Range: | -65 to +70°C |
Operating Temperature Range: | -10 to +55°C |
Weight: | 230g |
I have made
measurements on that tube with the following results:
CD47/GR-411 (used):
Ufiring = 140-145 V
Umaintaining = 142-148V (@ Ik = 25mA)
CD47/GR-414 (NIB and used):
Ufiring = 120-133 V
Umaintaining = 143 - 155V (@ Ik = 25mA)
So what we see:
Both will work on my power supply wich has 160 to 180 V
adjustable. If I would use a 250V supply, the losses would
increase. So I will go right with 170 Volts.
I can use it for my second and third CD47 clock.
Downloads/Datasheets:
Sie finden passende Datenblätter
im Datenblattarchiv.
Suchen sie dort nach dieser Type und deren Vergleichstypen.
You'll find the matching datasheets in
the datasheet archive.
Search for this type and its substitutes there.
Back
to Dieter's Nixie Tube Page
eMail to Dieter
Impressum & Datenschutz