Z502S (Valvo)
Dekatron counting tube


Bi-directional double-pulse decimal counting tube.
Neon
filled.

The following pictures show the tube spinning.
Of course, only one of the cathodes is glowing, but the shutter speed of the camera generates different pictures:

A normal shutter speed of the camera:

A high shutter speed of the camera:

A low shutter speed of the camera:

By night, with low shutter speed of the camera:

An animation of a spinning Dekatron:

Röhrendaten/Tube Data:

German English    
Röhrentyp Tube type   Z502S
Hersteller Brand   Valvo
Vergleichstypen Substitutes   GS10C, GS10C/S, M2465-402, CV2325
Zähl-Richtung Counting direction   bidirectional
Arbeitsweise Operation   double pulse
Art Sort   SEL
Sockel Base   B12E
Fassung Socket   B12E
Nullposition Zero position   pin10 +6°
Zähl-Schritte Counting steps   10
Anzahl der Hilfskathoden Number of guides   2
Gasfüllung Gas filling   Neon
Röhrendurchmesser maximal Tube diameter max. mm 33,1
Röhrenhöhe maximal Tube height max. mm 88,5
       
max. Zähl-Geschwindigkeit Max. counting speed kHz 4
Betriebsspannung minimal Supply volt. min. V 400 (350)
Betriebsspannung typisch Supply volt. typ. V 475
Brennspannung minimal Maintaining voltage min. V 186
Brennspannung typisch Maintaining voltage typ. V 191
Brennspannung maximal Maintaining voltage max. V 196
Anoden bzw. Kathodenstrom min. Anode/cath. current min. µA 250
Anoden bzw. Kathodenstrom typ. Anode/cath. current typ. µA 340
Anoden bzw. Kathodenstrom max. Anode/cath. current max. µA 550
Netzteil Leistung minimal Power supply power min. mW 261,25
Anodenwiderstand typisch Anode resistor typical 820
Spannungsdifferenz zw. 2 Kath. max. Voltage between 2 cathodes max. V 140
Transferspannung minimal Transfer voltage min. V 35
Hilfskathodenvorspannnung minimal Guide bias volt. min. V 35
Hilfskathodenvorspannnung Impulsbetrieb typ. Guide bias typ pulse op. V 40
Hilfskathodenimpulsspannung Guide signal voltage pulse Vp 100
Hilfskathodenimpulsdauer minimal Guide signal pulse duration min µs 75
Hilfskathodenimpulsdauer (Rechteck) min. Guide rectangle pulse duration min. µs 65
Kathodenwiderstand typisch Cathode resistor typical 120
Resetimpulsspannung Reset pulse voltage min. V -120
       
Anschlussbelegung: Pinout:    
PIN 01 PIN 01   K0
PIN 02 PIN 02   K9
PIN 03 PIN 03   K8
PIN 04 PIN 04   K7
PIN 05 PIN 05   K6
PIN 06 PIN 06   K5
PIN 07 PIN 07   K4
PIN 08 PIN 08   K3
PIN 09 PIN 09   K2
PIN 10 PIN 10   K1
PIN 11 PIN 11   G2
PIN 12 PIN 12   G1
Kappe in der Mitte center cap   A

Pinout & Outline:

The Z502S Dekatron Spinner by Dieter:
The following schematic shows how to use the tube for a Dekatron spinner.
If you don't know what a Dekatron spinner is click here!
The circuit can be used at 100-125VAC/50-60 Hz or 210-240VAC/50-60Hz.

Downloads/Datasheets:

Sie finden passende Datenblätter im Datenblattarchiv.
Suchen sie dort nach dieser Type und deren Vergleichstypen.

You'll find the matching datasheets in the datasheet archive.
Search for this type and its substitutes there.


Back to Dieter's Nixie Tube Page

eMail to Dieter
Impressum & Datenschutz